cavitron jet plus manual

Installation and Service Manual. Air Polishing Prophylaxis System with. Detartreur ultrasonique et systeme combine de detartrage et de polissage a l air. View and Download DENTSPLY Cavitron JET Plus installation and service manual online. Cavitron JET. With the Cavitron JET Plus Combination System OFF, unscrew the powder bowl cap. Verify the powder bowl is empty. Turn the system ON for 15 seconds to. This short video will. Safco Dental Supply sells Cavitron Jet Plus by Dentsply Professional at discount prices. We offer free shipping and the highest quality service. 10 Dec 2013. A short tutorial to demonstrate how to setup your Cavitron Prophy-Jet Ultrasonic Scaler with Tap-On Technology. For dental professionals. Cavitron Plus with NEW Tap-On Technology activates scaling with a single tap of the foot pedal, allowing your foot to rest as you scale, designed to improve. Combination ultrasonic scaler and air-polishing unit. Dentsply Cavitron Plus SPS Ultrasonic Scaler Gen 131 - 2-Year Warranty. Cavitron Bobcat Pro Dental Ultrasonic Scaler. Cavitron JET Plus Ultrasonic Scaler and Air Polishing Prophy System. Cavitron Plus Ultrasonic Scaler with Tap -On. Cavitron Jet Plus User s. The Cavitron Jet Plus SPS Gen 132 is a dental ultrasonic scaler and air polisher. It can be used for all general supra and. Reload to refresh your session. Reload to refresh your session. You need to upgrade your browser. Prophy Mode auto cycles- short, medium, long - automatically alternate between air polish and rinse without a need to touch the foot pedal. Additional power option include single-push turbo mode for up to 25% greater power and hands-free boost activation by pressing the pedal to the floor. Extended Low Power Range, BlueZone, designed for improved patient comfort. Enhanced efficiency Additional power options include single-push turbo mode for up to 25% greater power and hands-free boost activation by pressing the pedal to the floor.

Finer water control allows for precise and convenient adjustment of lavage on the handpiece to the preferred setting. PLUS all the benefits you have come to expect from Cavitron Systems BlueZone for improved patient comfort. Autoclavable handpiece provides assurance against cross-contamination. Single-push rinse and purge modes. Items included: (1) Cavitron JET Plus Ultrasonic Scaler and Air Polishing System with Handpiece Cable with Swivel (1) Tap-On Technology Wireless Foot Pedal (1) JET-Mate Sterilizable, Detachable Handpiece (1) JET Air Polishing Insert (1) Prophy-JET Sodium Bicarbonate Powder 13 Oz. Bottle (1) JET-Fresh Aluminum Trihydroxide Prophy Powder 13 Oz.Cookies are files stored in your browser and are used by most websites to help personalize your web experience. By using this site, you agree to our For information on how we process or monitor your personal data, please click. If you want the best, you want Cavitron products. And if you care about your patients - and your practice - choose the best. Additional power options include Finer water control. Account Number Password Forgot password. Log In Securely Create My Account Account Number Password Forgot password. Log In Securely Click here for information on infection control supply disruptions. Redemption coupon will be included with your order. One tap on the foot pedal activates a 4-minute ultrasonic power or rinse mode, freeing you to relax or move your foot instead of holding it on the pedal. Another tap disables the ultrasonic power and water flow.See package for details and enrollment instructions.) 3 year warranty This product received a 93% clinical rating. It includes Tap-On technology which allows the operator to remove their foot from the pedal and rest, avoiding the discomfort associated with continuous applied pressure. When the pedal is tapped to turn off the scaler, there is a slight delay before the water flow turns off.

The Tap-On mode can be disabled if a user prefers traditional foot pedal control. Like Tap-On technology, this feature eliminates the need to touch the foot pedal, which also increases efficiency. Summary of Contents for DENTSPLY Cavitron JET Plus. Cavitron Jet Plus scaler with SPS system. We have 2 DENTSPLY Cavitron JET Plus manuals available for free PDF download: Installation And Service Manual. Please carefully follow the procedural guidelines in this manual regarding. Directions for Use and Service Manual instructions for Foot Control synchronizing. Handpiece heats up. 1. Insufficient water to. Connect POWER supply. Connect WATER supply by pushing BLUE water hose into Symbol: means o. water port. A ir Connect HANDPIECE to cable. Install BATTERIES in wireless Connect AIR supply (if equipped) foot pedal unit. Tap wireless foot pedal one time. Purge Turbo Boost Turbo: When pressed, Boost: Temporary, hands- Purge: Remove insert increases power delivered free activation by pressing. Maintain a distance of no more than 10 feet (3 meters) between the base unit and Tap-On Foot Pedal during the synchronization process. Turning the knob clockwise increases the distance the insert tip moves (stroke) without changing the frequency;. Replace batteries as instructed in Service Indicator section 7.9. Illuminates when the system is not functioning properly. This display has three distinct modes. Turn counter-clockwise toward 1 to decrease flow. When the buttons are released, they will blink an additional 6 times to confirm Tap-On has been For detailed information, contact your local DENTSPLY disabled. Professional Representative or authorized DENTSPLY Tap-On Technology feature can be enabled by Professional Distributor. DENTSPLY recommends that the clinician familiarize themselves with the available power levels throughout the power knob rotation in both normal and turbo modes.Verify the powder bowl Remove the JET-Mate handpiece, clean and sterilize is empty.

A 10-pack of replacement filters is available Turn the System ON and check for strong air flow by ordering Part Number 90158 from your local DENTSPLY from the center tube of the powder bowl. Professional distributor. Although service and repair of the Cavitron JET Plus Check the insert for damage and that it is properly Combination System should be performed by DENTSPLY installed in the handpiece. Air Polishing System is warranted for TWO YEARS from date Symptom: of purchase. Not for operating theatres. Remote Communication Frequency: 2405 to 2480 MHz Power: The customer or the user of the Ultrasonic Scaler should assure that it is used in such an environment. The customer or the user of the Model G137 should assure that it is used in such an environment. IEC 60601 Compliance Electromagnetic environment - guidance Immunity test. The customer or the user of the Model G137 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Model G137 as recommended below, according to the maximum output power of the communications equipment. Assurez- vous qu’il est stable et qu’il repose sur ses quatre pattes. Placez l’interrupteur principal sur la position OFF (0).Si se siguen los lineamientos de pulido por aire. NO LO FUERCE. Professional. La pieza de mano JET- 1. Prueba de IEC 60601 Nivel de. Limpie la boquilla con el utensilio que se suministra.Den Batteriefachdeckel aufsetzen und die Schraube festziehen.Vor Gebrauch des angezeigt).Austauschfilter 2. Den Deckel von der Pulverschale abschrauben.Der Kunde oder Benutzer des Modells G137 muss sicherstellen, dass dieses in einem solchen Umfeld verwendet wird.Keine oder schlechte Pulverdeckel locker. Netzschalter auf AUS (O) stellen.Tap-On Colpire il pedale senza fili una volta, velocemente.

Ruotando la manopola in senso orario si aumenta la distanza entro la quale si muove la punta dell’inserto (la corsa) senza modificare la frequenza;. Sostituire le batterie Indicatore di servizio come indicato nella sezione 7.9. Si illumina quando il sistema non funziona correttamente. Ruotare in senso antiorario verso l’1 per diminuire il flusso. Altre sostanze o additivi l’intervallo operativo del comando. Tenere il manipolo possono ostruire il sistema e annullare la garanzia. Per sopra una vaschetta o uno scarico.Verificare Tenere il manipolo su una bacinella o su uno scarico e che la vaschetta sia vuota.I gruppi DENTSPLY Professional. Qui di seguito sono comunque filtro sostitutivi possono essere ordinati con il numero parte indicate alcune procedure di base per la risoluzione di 90088 presso il distributore locale DENTSPLY Professional. Premere il pedale Tap-On per 2 secondi. Se il lampeggio continua, passare alla fase manipolo successiva. Il cliente o l'utilizzatore dell'ablatore ad ultrasuoni deve accertarsi che esso venga utilizzato in tale tipo di ambiente. Il cliente o l'utilizzatore del modello G137 deve accertarsi che esso venga utilizzato in tale tipo di ambiente.Pulire l’ugello utilizzando lo strumento in dotazione. Filtro unidirezionale bloccato. Nessuno sfiato d’aria Il sistema funziona: Livello della polvere molto basso o vaschetta della polvere vuota. Ltd De-Trey-Strasse 1 17 Michael FARADAY 11-21 Gilby Road 78467 Konstanz. Registrieren Sie sich jetzt. This guide contains basic operating instructions, adjustments, and maintenance for the A-dec 511 dental chair. Save these instructions for future use. Save Shipping They are the bisecting angle technic Heliocol collectors are sleek and. You must have JavaScript enabled in your browser to utilize the functionality of this website.

Contains: One Cavitron JET Plus Ultrasonic Scaler and Air Polishing System, three JET-Mate Handpieces, two Cavitron Air Polishing Inserts, one Tap-On Technology Wireless Foot Pedal, one Prophy-JET Sodium Bicarbonate Prophy Powder, one JET-Fresh Prophy Powder, four ultrasonic inserts (which includes one FitGrip Insert), 3-year warranty and a 3-year Cavitron Care Maintenance Plan. The cost of equipment and supplies is very reasonable and they are very easy to work with. Thank you so much. Dr. Omowumi Ladipo of Humble, Texas. A quick press on the Tap-On Wireless Foot Pedal engages the unit, which remains active until the foot pedal is tapped a second time. As a result, the clinician’s foot remains off the pedal in a neutral, relaxed position during the scaling procedure. This feature allows dental hygienists to individualize each patient’s treatment based on the level of deposit to be removed. Because the water control is located on the base of the handpiece, dental hygienists need not turn away from the patient to make changes. Also, the numbers on the handpiece allow for simple acclimation to clinicians’ preferred settings. Hands-free activation of the boost mode is achieved by simply pressing the foot pedal to the floor. Boost mode provides a short power surge, while the new Turbo mode is designed for occasions that require a sustained power increase. March 2014;12(3):69. Learn how your comment data is processed. We'll assume you're ok with this, but you can opt-out if you wish. No installationFully autoclavable,Large powder reservoir is ideal for handlingCan be used chairsideComplete Unit-4-HoleContains: 1 unit with autoclavable handpiece, 1Autoclavable HandpieceSpray-Head TubesCombination ultrasonicComplete UnitSee page 419 for Cavitron JET Plus Package. Fax: 800.732.7023Cavitron Prophy-JetAir Polishing and.

Prophylaxis System withDesigned to improve efficiency and reduceUnit activates with just aProphy Mode Auto Cycles automatically cycleClinicians can easily select the prophy cyclesComplete UnitCavitron Prophy-Jet sodium bicarbonate prophyHandpiece SheathsPROPHY-JET Air-Polishing. System with Jet-Mate handpiece andAir Polishing Nozzle forDENTSPLY ProfessionalSingle PackSteri-Pak 3-PackCleaning ToolPortable air-polishingThe position of theComplete Unit.Ea. 1,689.99. Specify. Midwest (601-1257) NSKDENTSPLY Professional. Single PackHandy 3.0 PERIO. Hu-Friedy EMS. Portable air-polishingComplete Unit.Ea. 1,989.99. Specify:Hu-Friedy EMS. Tabletop air polisher for effectively andReliable, fast, quiet,Complete UnitCLASSIC powder, 1 water hose with quickAir Polishers continued on next page. Call To Order: 800.372.4346 8am-9pm (ET). Note: Unit accepts all 30K Inserts and 30K Pec Endosonic Inserts. 770-8187501. An under mount 30K scaling unit that utilizes the existing the G98A platform. It uses one of the dental hoses to activate the Cavitron SPS Self Install Scaler to supply cooling water to the Cavitron Steri-Mate handpiece. The self install concept will free-up counter space, eliminate the need for a separate foot pedal, and increase the convenience of using the ultrasonic scaler by placing it chair-side. The unit is self-install, no tech required. At this time, all infection control products are non-returnable.Please try again. Please try again in a few moments. Please check our latest Enter a larger quantity or select a different vendor.Learn more Many trusted vendors have beenThe products that you purchase from Net32In such cases, should you not beAt no time willPlease follow the link(s) below to provide your information.Follow us on Pricing subject to change. Bottle, 1 JET-Fresh Aluminum Trihydroxide Prophy Powder 13 Oz. Bottle (Na-free), 1 Auxiliary Cable for Foot Control, 1 4-Pack ?AA?

Batteries, 2 Year Warranty on Unit only, Instructional Video and Manual Tap-On Technology is designed to reduce leg and ankle discomfort associated with continued foot pedal usage “ A single tap activates scaling, allowing you to rest your foot during the procedure Prophy Mode auto cycles- short, medium, long - automatically alternate between air polish and rinse without a need to touch the foot pedal Additional power option include single-push turbo mode for up to 25% greater power and hands-free boost activation by pressing the pedal to the floor Extended Low Power Range, BlueZone, designed for improved patient comfort Batteries Instructional Video Manual See significant discounts. ENGLISH 51 Please read carefully and completely before operating unit. Cavitron JET Combination System UltrasonicScaler and Air Polishing Prophylaxis System Directions For Use Veuillez lire soigneusement et compltement avant dutiliser le systme. Por favor lea la totalidad de las instrucciones cuidadosamente antes de hacer funcionar la unidad. Systme combin Cavitron JET Dtartreur ultrasonique et systme deprophylaxie par polissage lair Mode demploi Sistema combinado Cavitron JETEscarificador ultrasnico y unidad profilctica de pulido neumtico Instrucciones para el uso ENGLISH 1 ENGLISH Cavitron JET Combination System UltrasonicScaler and Air Polishing Prophylaxis System Introduction Directions For Use DENTSPLY Preventive Care is an ISO9001 and EN46000certified company. The Cavitron JET Combination System isclassified by Underwriters Laboratories Inc. The Cavitron JET dental prophylaxis system is a precisionengineered and manufactured instrument. It contains controlsand components for ultrasonic scaling and air polishing modes. The System operates by converting ordinary AC house currentinto high frequency current. The ultrasonic system consists oftwo parts: an insert, and the SPS (Sustained PerformanceSystem) electronic system. The SPS system incorporates twoclosed loops.

One provides automatic tuning (operating frequencyis adjusted to be at resonance for each insert), the second loopautomatically controls the tip stroke over different workingconditions. The Cavitron JET Combination System produces30,000 microscopically small strokes per second at the insertsworking tip. This combined with acoustic effects of the coolantwater, produces a synergistic action that literally powers awaythe heaviest calculus deposits while providing exceptionaloperator and patient comfort. With the addition of the Air Polishing function, your Cavitron JET becomes a complete prophylaxis system. Mode selection isautomatic when you place the Airpolishing insert nozzle or one ofthe interchangeable 30K ultrasonic inserts into the handpiece. Technical Support There are no serviceable parts in this device. Refer all service to aqualified service repair facility. For technical support and repairassistance in the U.S. call 1-800-347-7412 Monday throughFriday, 8:00 AM to 5:00 PM (Eastern Time). For other areas,contact your local DENTSPLY representative. Ifyour dealer is unable to assist you, call 1-800-989-8826 Mondaythrough Friday, 8:00 AM to 5:00 PM (Eastern Time). For otherareas, contact your local DENTSPLY representative. Caution: U.S. Federal Law restricts this device to sale by or on theorder of a dentist. Cavitron JET Combination System Ultrasonic Scaler and Air Polishing Prophylaxis System Please read carefully and completely before operating unit. Excessive heat may damage the Systemselectronics. Place the System where air is free to circulateon all sides and beneath it. The System is portable, but must be handled with carewhen moving. Equipment flushing and dental water supply systemmaintenance are strongly recommended. See Water Supply under Section 9: System Care. Close the coolant water shut-off valve to the System everynight before leaving the office. The use of an in-line waterfilter is recommended. 2.

1 Contraindications Ultrasonic Systems should not be used for restorativedental procedures involving the condensation ofamalgam. For best performance, use only ultrasonic insertsmanufactured by Dentsply Preventive Care. Use only Cavitron Prophy-Jet Cleaning Powder. 1.1 Ultrasonic procedures All general supra and subgingival scaling applications. Periodontal debridement for all types of periodontaldiseases. For patients with a history of sensitivity to ultrasonics. Endodontic procedures. 2.2 Warnings Persons fitted with cardiac pacemakers have beencautioned that some types of electronic equipment mightinterfere with the operation of a pacemaker. Although noinstance of pacemaker interference has ever been reportedto DENTSPLY, we recommend that the handpiece andcables be kept at least 6 to 9 inches (15 to 23 cm) awayfrom any pacemaker and pacemaker leads during use. Do not direct the air polishing stream at soft tissue orinto the sulcus. Air Polishing The use of an air dryer on the compressor line supplyingthe System will prevent condensation from forming inthe air line which in turn may cause caking of the airpolishing cleaning powder and clogging the lines at theair polishing tip. Prophylaxis of orthodontic patients. Preparing tooth surfaces prior to bonding and sealantprocedures. 3.2 Precautions for Ultrasonic ProphylaxisProcedures Like a toothbrush, ultrasonic inserts wear out withuse. Inserts with just 2 mm of wear lose about 50% oftheir scaling efficiency. In general, it is recommended thatultrasonic inserts be discarded and replaced after 2 mm ofwear to maintain optimal efficiency and avoid breakage. If excessive wear is noted, or the insert has been bent,reshaped or otherwise damaged, discard the insertimmediately. Aude Gehrmann-De Ridder.The computed torque plus compensation controller of robot manipulators, that was. Liver resection using cavitron ultrasonic surgical aspirator (CUSA) versus harmonic scalpel: A retrospective cohort study.

Air Polishing Prophylaxis System. Installation and. Clinical studies and independent research have proven that no other method of supra- and subgingival calculus removal can surpass the speed, efficiency, and versatility of ultrasonic scaling. The Cavitron Plus System has extended the SPS technology by spreading out the Blue Zone range, providing finer resolution to the power settings. With the addition of air polishing capabilities in the Cavitron JET Plus Combination System, your Cavitron JET Plus system becomes a compact prophylaxis center that maximizes the time spent performing scaling and polishing procedures and minimizes the need for strenuous calculus and stain removal with hand instruments. Clinical studies have proven that air polishing is far superior to traditional cup and pumice for stain and plaque removal.Website: www.professional.dentsply.com Rx Only: This product is intended for use by qualified dental professional healthcare providers. It contains controls and components for ultrasonic scaling and air polishing modes. The Cavitron JET Plus Combination System is classified by Underwriters Laboratories Inc.The Cavitron JET Plus Combination System complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Although no instance of interference has ever been reported to DENTSPLY, we recommend that the handpiece and cables be kept 6 to 9 inches (15 to 23 cm) away from any device and their leads during use. To order supplies or replacement parts in the U.S., contact your local DENTSPLY Professional Distributor or call 1-800-989-8826, Monday through Friday, 8:00 A.M. to 5:00 P.M. (Eastern Time). For other areas, contact your local DENTSPLY Professional Representative. There are a variety of pacemakers and other medically implanted devices on the market.

Clinicians should contact the device manufacturer or the patient’s physician for specific recommendations. This unit complies with IEC 60601 Medical Device Standards. A Dental Healthcare Professional should disconnect the system from the central water source. The Cavitron DualSelect system can be attached to this unit and operated as a closed system until the advisory is cancelled. Therefore, this powder is not recommended for patients on a sodium restricted diet. Inserts with just 2 mm of wear lose about 50% of their scaling efficiency. In general it is recommended that ultrasonic inserts be discarded and replaced after one year of use to maintain optimal efficiency and avoid breakage. Excessive heat may damage the system’s electronics. See Section 9: System Care. Companies that manufacture, repair or modify inserts carry the sole responsibility for proving the efficacy and performance of their products when used as a part of this system. For operator and patient safety, carefully practice the infection control procedures detailed in the Infection Control Information Booklet accompanying your System. A filter mounting bracket is included for hanging the air filter. The clear bowl should hang downward allowing for moisture separation and drainage of water from the air filter. See Sections 6.1 and 9. As a medical device, this product must to be installed in accordance with applicable local, regional, and national regulations, including guidelines for water quality (e.g. drinking water). As an open water system, such regulation may require this device to be connected to a centralized water control device. JET-Mate Detachable Sterilizable Handpiece 11. Prophy Handpiece Cleaning Wire (not shown) 12. Efficiency Indicator for Cavitron Inserts 14. Literature Packet 16. If your office has more than one Cavitron JET Plus system, it is recommended that you mark the foot control and base unit for easy reference as to which foot control operates with which base unit.

Disconnect the water supply line from the dental office water supply. If a quick-disconnect connector is attached to the end of the hose, relieve the water pressure by pressing the tip of the connector in an appropriate container and allow water to drain. Turn foot control over and using a Philips screwdriver carefully remove battery cover screw and battery cover. If applicable, remove used batteries and install two new “AA” batteries as shown. Do not depress foot control while installing batteries. If the light does not blink, check the batteries. If the batteries are good and the light doesn’t blink, a communications error may exist. Should a replacement foot control be necessary, synchronization will be required prior to system operation. Perform the following steps to synchronize the foot control with the base unit. Press ring to release air supply tube. 1. 2. 8 Turn the Main Power switch located at the center front underside of the system to the OFF (O) position. Install a new set of “AA” batteries into the foot control (See Section 6.9) Leave the battery cover of the foot control open so the red push button is accessible. 3. 4. 5. 6. 7. 8. 9. 10. Maintain a distance of no more than 10 feet (3m) between the base unit and foot control during the synchronization process. Remove any inserts from the handpiece and adjust the Power Level Control out of Rinse Mode. Turn the Main Power switch to the ON (I) position and wait for the Diagnostic Display graphics to light (refer to Section 7.2). While all graphics are lit, press the Purge button, located on the Diagnostic Display. The graphics will begin to blink in a sequential pattern, representing the synchronization mode. This mode will last 5 to 6 seconds. During this mode, press the red button located in the battery compartment of the foot control. This will complete the synchronization process. Synchronization is successful when all graphics blink at the same time. Replace battery cover and the screw.

In the event communication cannot be established, temporarily use the supplied Auxillary Foot Control Cable to connect the Foot Control directly to the unit. 9 SECTION 7: Cavitron JET Plus Combination System Description 7.1 System Controls Ultrasonic Power Level Control Turn knob to select the ultrasonic power level for operation. Turning the knob clockwise increases the distance the insert tip moves (stroke) without changing the frequency; turning the knob counterclockwise decreases the distance the insert tip moves (stroke) without changing the frequency. The Blue Zone is a low-power range for effective subgingival debridement and improved patient comfort during definitive therapy. Rinse Turn the ultrasonic power level control knob fully counterclockwise until a “click” is heard. Rinse mode is for use during an ultrasonic scaling procedure when lavage is desired with minimal cavitation. Automatically selects air polishing or scaling mode. See Section 7.3 Powder Flow Control Rotate clear Powder Flow Control to adjust powder flow rates. For minimum powder flow turn control clockwise to “L”. For maximum flow turn to “H”. Diagnostic Display See Section 7.2 Handpiece Holder Securely holds the system’s handpiece, or cable connector when handpiece is not installed. Handpiece must be oriented as shown and pressed gently into position. Dual Position Foot Control Operates the system in Boost and normal power modes. See Section 7.6 10 7.2 Diagnostic Display Indicators and Controls Blue Zone Indicator Lights when the Power Level Control is positioned in the Blue Zone of the power scale. Ideal for effective subgingival debridement and greater patient comfort. Rinse Indicator Lights when the Power Level Control is turned fully counterclockwise. Rinse mode provides lavage to flush the procedural area with minimal cavitation. Boost Indicator Lights when the Boost Mode has been activated with the Foot Control.

Low Battery Indicator Lights when the foot control battery power is approaching end of life. Replace batteries as instructed in Section 6.9. Service Indicator Lights when the system is not functioning properly. Power Indicator Lights (3 sec. Purge Control Lights when the Purge function is activated. To activate Purge, remove insert from the handpiece, and press the Purge button. Water will purge through system for 2 minutes. For optimal efficiency, turn the handpiece lavage control to maximum water flow. To deactivate mode during the 2 minute cycle, press Purge button again or press foot control. Refer to Section 10.1 for Troubleshooting guidelines. The Purge Control is also used during the Foot Control Synchronization process. Clockwise increases flow at insert tip, counterclockwise decreases flow. The flow rate through the handpiece also determines the temperature of the lavage. Lower flow rates produce warmer lavage. Higher flow rates produce cooler lavage. If the handpiece becomes warm, increase the flow rate. With experience the Dental Healthcare Professional will be able to determine the best flow rate setting for optimum operating efficiency and patient comfort. Swivel Feature Reduces cable drag as handpiece rotates during procedures. Soft Nozzle Grip Provides an ergonomic and comfortable grasp of the handpiece. The grip is a replaceable wear component. Prior to use, verify that the grip is flush with the hard plastic of the insert port. Powder Delivery Port Creates an airtight seal between the air polishing insert and the handpiece. Replace when wear is noticed or powder is leaking at nozzle interface. See enclosed literature for specific information. O-Ring Provides seal for handpiece coolant. O-ring should be replaced when worn. Insert Tip Shape and size of tip determines access and adaptation. Preheated Lavage directed to tip. Finger Grip Connecting Body Transfers and amplifies mechanical motion of stack to insert tip.